Section 905.150 — Sanitary Dump Stations

  1. Section 905.150 — Sanitary Dump Stations
    Incorrect. The correct answer is highlighed in green below.

    A sanitary dump station with a disposal system must be designed on the basis of __ gallons per day per unsewered recreational vehicle site
    1. 20
      (905.150-a-1) A sanitary dump station with a disposal system shall be designed on the basis of 20 gallons per day per unsewered recreational vehicle site.
    2. 10
    3. 50
    4. 25
  2. Section 905.150 — Sanitary Dump Stations
    Incorrect. The correct answer is highlighed in green below.

    Ancillary requirements include a (an) __________ self closing cap
    1. Electrical
    2. Hand operated
    3. Infrared
    4. Foot operated
      (905.150 c-2) Ancillary Requirements. A sanitary dump station shall be provided with the following: 1) A concrete pad sloped at least one inch per 10 feet to a drain. This pad shall extend at least 2 feet in every direction from the drain, and shall have at least a 2 inch high curb around the outside perimeter of the pad as indicated in Appendix A: Illustration V of this Part. 2) A foot-operated, self-closing cap which forms a tight seal with the drain shall be provided. 3) The sewer line from the drain to the tank shall be at least 4 inches in diameter and constructed of material approved under Section 905.20(f). It shall be installed to maintain at least a 10 foot horizontal separation between the water and sewer line, and the water line and the tank. 4) A water supply distribution tap for flushing the pad shall be provided. The water supply line to the tap shall be of materials, location, and construction in accordance with the Illinois Plumbing Code (77 Ill. Adm. Code 890), and shall be provided with approved, properly installed back siphonage protection. No "stop and waste" valves will be allowed on this tap. This water tap shall be posted, "Not for Human Consumption. Use for Flushing and Cleaning Purposes Only."